NO. 711PREMOULDED MEMBRANE® VAPOR SEAL
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Width | Length | Weight | |
| Sheets | 48" (1.22m) | 8' (2.44m) | 65 lbs./100 sq. ft. (29.48 kg) |
| Rolls | 48" (1.22m) | 50' (15.24m) | 60 lbs./100 sq. ft. (27.22 kg) |
Estimating
When estimating the amount of PMPC
required, figure the actual area plus 20% for overlap when using sheets...for
rolls, figure actual areas plus 12% for overlap.
Handling Suggestions
CUTTING...PREMOULDED MEMBRANE VAPOR
SEAL can be cut with a roofer's or linoleum knife using a straight edge.
BENDING...To facilitate bending at a change in plane such as at corners
or footings, lightly heat the board at the bending area.
STORAGE...Handling of PMPC is not critical because of its strength; however,
it is advisable to stack the material on smooth ground or a wood platform
in storage or at the excavation site. This will eliminate the possibility
of the PREMOULDED MEMBRANE sheets deforming or warping.
POINTING...Pointing with SEALTIGHT Pointing Mastic should be done wherever
an edge is exposed to prevent water from traveling under a sheet.
STOPS MOISTURE MIGRATION IN HORIZONTAL CONCRETE
APPLICATIONS
The Ultimate Vapor Barrier to Eliminate Costly Moisture Damage
Over 80% of the moisture entering a structure originates in the site...it
moves from the grade into the structure both as a liquid (capillarity)
and as a gas (vapor). The only effective way to eliminate the costly problems
of excessive moisture migration is to completely isolate the structure
from the site during original construction with the installation of a
true vapor seal membrane that is both waterproof and vaporproof. Material
that is vaporproof is completely waterproof: however, not everything that
is waterproof is vaporproof. PREMOULDED MEMBRANE VAPOR SEAL with PLASMATIC
CORE is both waterproof and vaporproof.
While tremendously strong, even the best concrete is porous. Uncontrolled
vapor will move through it, causing dank musty smells...rust and condensation...damage
to mechanical equipment...cracked plaster...chipped paint, efflorescence...warped
floors, etc. The installation of a true vapor seal under the concrete
floor slabs will stop moisture migration.
A true vapor seal must also be durable and tough enough to withstand normal
handling, foot traffic, aggregate impact and backfill abrasion. One tear,
or a few pinholes will destroy the entire purpose of the installation.
Plastic films, laminated film and paper combinations, reinforced building
papers and saturated roofing felts are semi-permeable at best, and will
permit the passage of air (vapor) through them. Additional information
on the hydrologic cycle may be found in W.R. Meadows Hydrologic Cycle
Manual available upon request.
SEALTIGHT PMPC offers the construction industry a positive, easy to install,
economical, true vapor-proofing system solution.
|
Roofer's Knife |
Caulking Gun |
Roller |
Application
HORIZONTAL INSTALLATIONS...ON OR
BELOW GRADE: By installing PREMOULDED MEMBRANE VAPOR SEAL with PLASMATIC
CORE on the ground prior to placing the concrete floor, moisture will
be prevented from coming through the floor slab.
ABOVE GRADE...By placing PMPC on the intermediate structural slab, moisture
is prevented from filtering downward from mechanical floors dedicated
to heating and air conditioning equipment. This prevents damage to lower
floor levels.
HORIZONTAL APPLICATION... PREMOULDED MEMBRANE VAPOR SEAL with PLASMATIC
CORE can be applied directly over tamped grade, because it does not require
a gravel bed, a bed of sand and/or "crusher rock" prior to the
installation of the floor slab, although these practices are acceptable.
PMPC works equally well with either side up. However, in areas exposed
to prolonged, direct sunlight we recommend poly side up.
Material is placed in position by either the "Dutch Lap" method
with laps sealed with SEALTIGHT Catalytic Bonding Asphalt or by the "Butt-Joint"
method with joints sealed with SEALTIGHT Detail Strips. These methods
provide a permanent, monolithic vapor seal without voids or open seams.
If desired, on structural floor slabs of multi-level buildings, sheets
may be placed in a bed of hot asphalt for continuous adhesion.
| THE "DUTCH LAP" METHOD (Figure 1): The "Dutch Lap" method of applying PMPC on or below-grade horizontal areas. After removing the polyfilm at the 6" overlap areas, seal all laps with SEALTIGHT Catalytic Bonding Asphalt. Pressure roll or "walk-in" all laps to assure complete adhesion. |
|
|
| THE "BUTT-JOINT" METHOD (Figure 2): The Butt-Joint method of applying PMPC. The sheets are tightly butted together and "Butt-Joints" sealed with SEALTIGHT Detail Strips. The Detail Strip is centered on the joints of the felt side and rolled down with pressure for a positive seal. |
|
|
Sealing Procedures
All protrusions through the concrete
slab, such as sewer pipes, water pipes and utility inlets, must have a
positive seal between the protrusion and the PREMOULDED MEMBRANE. Place
a collar of PMPC at least 12" larger than the protrusion around the
protrusion. Seal in place with SEALTIGHT Detail Strips and point around
the protrusion with SEALTIGHT Pointing Mastic.
Accessories
BONDING ADHESIVES...SEALTIGHT Catalytic Bonding Asphalt:
A non-setting bitumen that provides a seal that will expand and contract
without breaking bond. Use to seal horizontal joints and rebars between
impaction sheets on footing. Packaging: 5 Gallon (18.93 liter) Pails.
COVERAGE: 5 Gallons per 1,000 ft² of material.
SEALTIGHT PM-5X...A hard-setting bitumen offering strong initial tack,
used to adhere PREMOULDED MEMBRANE to vertical surfaces. Packaging: 5
Gallon (18.93 liter) Pails.
SEALTIGHT Detail Strip...A sturdy, self-adhering, reinforced tape of polymeric
membrane that requires no additional adhesive. Provides a simple, easy
and economical method of effectively sealing horizontal and vertical butt
joints. Each strip is nominally 9" (.23m) wide and 50' (15.24m) long.
Has quick-strip release paper for ease of handling and application. Packaged
4 rolls per carton.
SEALTIGHT Pointing Mastic is used for sealing top horizontal terminations
or slab protrusions
Packaging: 5 Gallon (18.93 liter) Pails or 29 oz. (857.65 ml) Cartridges.
For full details, see Product Data Sheet No. 740.
| Adhesive | Joint Method | Per MSF of Membrane (Approx.) |
| Catalytic Bonding Asphalt* | Sheets: 6" (152.4mm) laps | 5 gal. (18.93 liters) |
| Rolls: 6" (152.4mm) laps | 3 gal. (11.36 liters) | |
| PM-5X | Sheets only | 40 gal. (151.4 liters) |
| Hot-Mop Asphalt* | Complete | 400-500 lbs. (180-230 kg) |
| Detail Strips | Butt-Joints | 416 linear ft. (126.8 meters) |
| Pointing Mastic** | Detail Strip, Edge Terminations | 2000 lineal ft./gal. (161.0 m/L) |
| *Based on minimum of 1/16" (1.59mm) film thickness | ||
| **1/8"x 1"x 200 lineal feet (3.18mm x 25.4mm x 60.96m) | ||
Precautions
PREMOULDED MEMBRANE VAPOR SEAL
does not negate the need for relief of hydrostatic heads. A complete drain
tile system should be placed on the exterior of the footing and, in severe
cases, on the interior of the footing as well. If applied to concrete
surfaces... repair any spalled areas... fill all voids and remove sharp
protusions.
Adhesive coverage ratios must be adjusted to compensate for surface irregularities
and additional coats may be required to provide proper adhesion. For maximum
concrete performance and durability, the floor slab concrete design should
provide for the lowest possible slump and yet assure complete hydration
of the concrete. Refer to Material Safety Data Sheet for complete Health and Safety Information.
This material last updated June, 2002.