Div. 07130  |
Product
Data
|
Guide Spec. No. 711
SEALTIGHT® PREMOULDED MEMBRANE®
| Specifier Notes: This guide specification
is written according to the Construction Specifications Institute
(CSI) Format. The section must be carefully reviewed and edited
by the Architect or Engineer to meet the requirements of the project.
Coordinate this section with other specification sections and the
drawings. |
SECTION 07130
PREMOULDED MEMBRANE VAPOR SEAL
| Specifier Notes: W.R. Meadows
SEALTIGHT PREMOULDED MEMBRANE VAPOR SEAL with PLASMATIC CORE is
a permanently bonded, multi-ply, semi-flexible core board for use
in on-grade, below-slab concrete waterproofing or vaporproofing. |
PART 1 GENERAL
1.1 SECTION INCLUDES
- A. Premoulded membrane vapor seal for horizontal
concrete applications.
1.2 RELATED SECTIONS
| Specifier Notes: Edit the list
of related sections as required for the project. List other sections
dealing with work directly related to this section. |
- A. Section 07100 - Dampproofing and Waterproofing.
1.3 REFERENCES
- A. ASTM E 96 - Water Vapor Transmission of Materials.
1.4 SUBMITTALS
- A. Comply with Section 01330 - Submittal Procedures.
B. Submit manufacturer's product data and application instructions.
1.5 DELIVERY, STORAGE, AND HANDLING
- A. Delivery: Deliver materials to site in manufacturer's
original, unopened containers and packaging, with labels clearly identifying
product name and manufacturer.
B. Storage: Store materials in a clean dry area in accordance with manufacturer's
instructions. Stack membrane on smooth ground or wood platform to eliminate
warping.
C. Handling: Protect materials during handling and application to prevent
damage or contamination.
1.6 ENVIRONMENTAL REQUIREMENTS
- A. Do not apply membrane on frozen ground.
PART 2 PRODUCTS
2.1 MANUFACTURER
- A. W.R. Meadows, Inc., PO Box 338, Hampshire, Illinois
60140-0338. (800) 342-5976. (847) 683-4500. Fax (847) 683-4544. Web
Site www.wrmeadows.com.
2.2 MATERIALS
A. Premoulded Membrane Vapor Seal: SEALTIGHT PREMOULDED
MEMBRANE VAPOR SEAL with PLASMATIC CORE.
1. Description: Permanently bonded, multi-ply,
semi-flexible core board.
a. Core: 3-plies. Plasmatic matrix encased
in 2 layers of pure-blown, high-meltpoint asphalt.
b. Liners: Core sandwiched between liners
of asphalt saturated felt and glass-mat liner.
c. Weathercoat: Asphalt weathercoat applied
to glass-mat liner and covered with polyethylene anti-stick sheet.
2. Water Vapor Transmission, ASTM E 96, Water
Method: 0.00 grains/square foot/hour.
2.3 ACCESSORIES
- A. Bonding Asphalt: SEALTIGHT CATALYTIC BONDING
ASPHALT.
B. Adhesive: SEALTIGHT PM-5X.
C. Joint Tape: SEALTIGHT DETAIL STRIP.
D. Pointing Mastic: SEALTIGHT POINTING MASTIC.
PART 3 EXECUTION
3.1 EXAMINATION
- A. Examine surfaces to receive membrane. Notify
Architect if surfaces are not acceptable. Do not begin surface preparation
or application until unacceptable conditions have been corrected.
3.2 SURFACE PREPARATION
- A. Prepare surfaces in accordance with manufacturer's
instructions.
3.3 APPLICATION
- A. Apply membrane in accordance with manufacturer's
instructions to provide a permanent, monolithic vapor seal without voids
or open seams.
B. Ensure accessory materials are compatible with membrane and approved
by membrane manufacturer.
C. Place membrane in position by either Dutch lap method with laps sealed
with bonding asphalt or by butt joint method with joints sealed with
joint tape.
D. Point exposed edges with pointing mastic to prevent water from traveling
under membrane.
E. Place membrane collar around protrusions through concrete slab, including
sewer pipes, water pipes, and utility inlets to create a positive seal
between protrusions and membrane. Seal in place with joint tape and
point around protrusions with pointing mastic.
F. Adhere membrane to vertical surfaces with adhesive.
3.4 PROTECTION
- A. Protect membrane from damage until placement
of concrete.
END OF SECTION
|